Compact PLC FP0

Compact PLC FP0

Data sheet FP0 Data sheet FP0 (2.63MB)
Manuals, software, other downloads Manuals, software, other downloads
Print this page Print this page
FP0 - incredibly small

The FP0 control unit's dimensions are W25 x H90 x D60mm. With up to 3 expansion units the FP0 can be expanded to a maximum of 128 points. Even so, the size is still only W105 x H90 x D60mm, a super compact design that breaks all previous common sense rules on small-scale PLCs. With the smallest ever attachment area, the FP0 is perfect for installation in machines, facilities, and control boards where the trend in miniaturisation continues.

The FP0 offers outstanding performance and flexibility:

  • Flexible configuration from 10 to 128 I/Os
  • 0.9µs per step ultra fast CPU processing
  • Large capacity with 2.7k, 5k and 10k memory size
  • Programme memory uses EEPROM
  • Analogue modules featuring 8 input channels or 2 input and 1 output channels
  • A second RS232 serial port for connection to intelligent devices or modems for telemetry applications
  • Built-in functions for interrupt processing, high-speed counting and pulse output for axis control 

PLC type C10 series (relay output) C14 series (relay output) C16 series (transistor output) C32 series (transistor output) T32 series (transistor output)
Number of inputs 6 8 8 16 16
Number of outputs 4 relay 6 relay 8 transistor 8
PNP/NPN
16 transistor
PNP/NPN
Transistor 16
PNP/NPN
Output capacity 2A 2A 0.1A 0.1A 0.1A
Digital I/Os (max.) 106 110 112 128 128
Analog I/Os (max.) 24 inputs / 12 outputs
Processing speed 0.9µs/step (basic instruction)
Memory  
Prog. memory type EEPROM (no back-up battery required)
Data memory type EEPROM (no back-up battery required) RAM (battery backup)
Programme capacity 2720 steps 5000 steps 10000 steps
Data register 1660 words 6144 words 16383 words
Special functions  
High-speed counter 1 phase / 4 points (10kHz) or 2 phases / 2 points (2kHz)
Pulse output 2 points (output frequency up to 10kHz)
Serial interfaces Up to two serial interfaces
Real-time clock Not available Available
Operating voltage range 24V DC (±10%)
Input only type
  • FP0-E8X, input 8 points
  • FP0-E16X, input 16 points

Relay output type
  • FP0-E8RS, input 4 points, output 4 points
  • FP0-E8YRS, output 8 points
  • FP0-E16RS, input 8 points, output 8 points
  • FP0-E32RS, input 16 points, output 16 points

Transistor output type
  • FP0-E8YP, output 8 points PNP
  • FP0-E8YT, output 8 points NPN
  • FP0-E16YP, output 16 points PNP
  • FP0-E16YT, output 16 points NPN

Transistor output type
  • FP0-E16P, input 8 points, output 8 points PNP
  • FP0-E16T, input 8 points, output 8 points NPN
  • FP0-E32P, input 16 points, output 16 points PNP
  • FP0-E32T, input 16 points, output 16 points NPN

 

 


Analogue units
   
Product FP0-A21 FP0-A80 FP0-A04V FP0-A04I
Input data Channels 2 8    
Voltage mode 0 to 5V / 
-10V to +10V
-100mV to +100mV
0V to 5V
-10V to +10V
   
Current mode 0 to 20mA    
Thermocouple mode K, J, T, R types      
Resolution 12-bit (1/4000)    
Conversion speed 
for voltage / current
for thermocouple

1ms / channel
560ms

2ms / channel
--
   
Output data No. of outputs 1 channel   4 4
Voltage mode -10V to +10V   -10V to +10V --
Current mode 0 to 20mA   -- 4 to 20mA
Resolution 12-bit   12-bit
Conversion speed 500µs / ch.   500µs / ch.
 
  • Multiple floating point calculation, accurate PID and auto-tuning can be performed with great efficiency.
  • An FPWIN Pro function block facilitates programming the FP0-A80 module.
  • An FPWIN Pro function block facilitates writing and reading channels 0 to 3 of the FP0-A04V and FP0-A04I modules.

Downloads
FPWIN Pro FB: FP0-A80 (0.24MB)
FPWIN Pro FB: FP0-A04xx (0.24MB)


RTD input unit
The new module determines temperatures with extreme precision and is easy to use. The temperature data obtained using the RTD (Resistance Temperature Detector) is converted to the digital value to be read by the FP0/FPS control unit.
  • The module can be easily installed in an existing system.
  • Multiple RTD types are allowed in one module, yielding a cost-effective solution.
  • The temperature data measured can be converted to either degrees Celsius or degrees Fahrenheit inside the FP0 RTD unit.
  • A broken RTD can be detected.


Available RTD types:
Pt100 (to IEC751), Pt1000 (to IEC751), Ni1000 (to DIN43760)


Product FP0-RTD6
Input channels 6
Input range Pt100: -200°C to +500°C
Pt1000: -200°C to +300°C
Ni1000: -30°C to +150°C
Resistor: -200W to 500W
Resolution 0.1K/°F, 0.01K/°F (selectable via output register)
Sampling cycle 0.1 or 1s for all channels (selectable via DIP switches)
Accuracy  
Pt100 Cycle 1s Ambient temp.: 25°C 0.3K (-10°C to +30°C
0.2%/1.4K (-200°C to +500°C)
Entire temp. range 0.35%/2.5K
Cycle 0.1s Entire temp. range 0.5%/3.5K
Pt1000 Cycle 1s Ambient temp.: 25°C 0.3K (-10°C to +30°C
0.2%/1.0K (-200°C to +300°C)
Entire temp. range 0.35%/1.7K
Cycle 0.1s Entire temp. range 0.5%/2.5K
Ni1000 Cycle 1s Entire temp. range 1K
Cycle 0.1s Entire temp. range 2K
Resistor Cycle 1s Entire temp. range 1# (20 to 2200#)
Cycle 0.1s Entire temp. range 2# (20 to 2200#)
Control FPWIN Pro provides the convenient function block "Read_RTD6" to read data from the input channels. It can be used by the FP0 RTD unit for all RTD types (Pt100, Pt1000, Ni1000 and Resistor).
Download
FPWIN Pro FB: RTD6 (0.24MB)


Thermocouple input units
 
Product FP0-TC4 FP0-TC8
Channels 4 8
Input range K, S type thermocouple: -100°C to 500°C
T type thermocouple: -100°C to 400°C
R type thermocouple: 0°C to 1500°C
Resolution 0.1°C
Sampling cycle 300ms: when using 2 channels for an input point
500ms: when using 4 channels for an input point
700ms: when using 6 channels for an input point
900ms: when using 8 channels for an input point
Accuracy Range for K and J (-100°C to 500°C): 0.8°C
Range for T (-100°C to 400°C): 0.8°C
Range for R (0°C to 99.9°C): 3°C
(100°C to 299.9°C): 2.5°C
(300°C to 1500°C): 2°C
Input impedance More than 1MW
Insulation method
  • Between thermocouple input terminals and control unit internal circuits: photo-coupler insulation/DC-DC insulation
  • Between thermocouple input terminal channels: PhotoMOS relay insulation
  • Up to three units can be added to each control unit enabling temperature control of up to 24 channels.
  • Broken thermocouples can be detected.

Download
FPWIN Pro FB: FP0-TC4, FP0-TC8 (0.24MB)


PROFIBUS
The FP0 DSP2 can operate either as a DP slave module or as a remote I/O system to which different decentralized inputs and outputs can be connected. A DIP switch can be used to switch between the two modes:
Mode 1: DP Slave module. Connect the FP0 or FPS CPU + expansion modules to the PROFIBUS network.
Mode 2: remote I/O. Connect up to three expansion modules without CPU to the PROFIBUS network.
In remote I/O mode, the unit can be connected to any PLC from any manufacturer that offers a PROFIBUS communication interface.

MEWNET-F
MEWNET-F is remote I/O system with reduced wiring that connects PLCs and I/O slave stations via 2-core cabling. By adding an I/O link unit to the FP0, you can link a master station PLC and FP0 inputs and outputs via the network.

S-LINK CPU
FP0 connects directly to the S-LINK for reduced wiring and simple installation. It can control up to 128 points for S-LINK-related devices. Similar to other FP0 units, up to three expansion units can be used for efficient I/O wiring.

CC-Link Slave Unit FP0-CCLS
This slave unit was developed for the open standard network CC-Link. By connecting this module to FP0R, FP0 or FP-X, data can be exchanged quickly between Panasonic PLCs and external devices, providing a vendor-independent data communication solution.

Relay output terminal FP0-RT8Y-6A
The FP0-RT8Y-6A unit provides reliable insulation between peripheral equipment and the PLC system, even for electrical loads up to 250VAC/6A. Standardized MIL connectors establish a direct connection to the FP0R or FP0 unit.

AC power supply FP0-PSA2
  • Incredibly small size: 90 x 30.4 x 60mm
  • Maximum output current: 0.7A (24V CD)
  • Multiple voltage input: 85 to 265V AC
  • Global approvals: UL/cUL, EN, CE
  • DIN-rail mounting



 